Quincy MA
Medford Wellington Services Co., Inc. provides complete air conditioning, heating and refrigeration services to the residents and businesses of Quincy, MA. we are available 24/7 to meet your services needs.
Read reviews from our commercial and residential clients in Bridgeport, CT to see why they consider us to be their trusted local HVAC and refrigeration contractor.
Local Reviews
for Quincy, MA
Bob S.
Commercial refrigeration repair for a Ice-O-Matic ice machine that is not producing solid ice. Unit is not reading the corrected temperature. Commercial ice machine installation for a new thermostat. Unit harvesting perfect now.
Bill K.
Commercial refrigeration repair for a Randell Reach-In Cooler that is running warm. Found unit to have a refrigerant leak in the condenser coil. Commercial refrigeration installation for a new condenser.
Anthony D.
Commercial HVAC repair for a Mitsubishi Ductless Split System that will not turn on. Found the unit responding to not calls to turn on, but power is flowing. Commercial HVAC install for a new control board. Unit is fully operational.
Adam F.
Commercial HVAC repair for a Trane RTU that is providing no air conditioning to the main retail area. Found the unit calling for AC but will not start the fan, or any other systems. Commercial HVAC install for a new relay for the fan, which will thena llow the rest to start as well. Call is complete.
Bob S.
Commercial refrigeration repair for a Manitowoc Ice Machine that is leaking water. Found the drain line to have developed a hole. Commercial refrigeration install for a new ice machine drain line.
Anthony D.
Commercial refrigeration repair for a Hobart low-boy reach-in that is currently completely shut down. Found unit to not be drawing any power. Commercial refrigeration installation for a new power supply.
Anthony D.
Commercial HVAC repair for a Captive Air exhaust fan that is not exhausting any of the kitchen air. Found the inline fan motor to have gone kaput. Commercial ventilation install for a new inline fan motor, unit is fully operational.
Adam F.
Commercial air conditioning repair for a Mitsubishi ductless split system that is leaking water on the indoor portion. Found the unit to have a condensate pump that has died. Commercial HVAC installation for a new condensate pump.
Dan R.
Commercial refrigeration repair of Manitowoc ice machine not producing ice. Discovered a failed water level probe. Commercial refrigeration install of a new water level probe. Tested and confirmed operation.
Ryan W.
Commercial HVAC repair of a Captive air make up air unit not supplying air into the space. Discovered that the blower motor failed. Commercial HVAC install of a new blower motor, pulley and belt. Adjusted for proper belt tension and amperage. Confirmed operation.
Daniel D.
Commercial refrigeration repair of a Heatcraft walk in freezer with ice build up in the evaporator coil. Discovered that the defrost time clock was stuck and would not advance, Commercial refrigeration install of a new defrost time clock. Tested and confirmed normal operation.
Paul A.
Commercial refrigeration repair of a Bohn walk in cooler with a failed evaporator fan motor. Found voltage leading to the motor. Commercial refrigeration install of a new evaporator fan motor. Tested and confirmed operation.
Robert S.
Commercial refrigeration repair of a Randell reach in cooler making a loud noise. Found the noise caused by failing bearings in the condenser fan motor. Commercial refrigeration install of a new condenser fan motor. Tested and confirmed operation.
Daniel D.
Commercial refrigeration repair of a Hoshizaki ice machine not producing ice. Found that the carbon water filters were old and restricting water flow. Commercial refrigeration install of a new carbon water filters. Tested and confirmed operation.
Yanni F.
Commercial HVAC repair of a Carrier roof top unit not cooling. Found that the compressor would not start due to a failed high pressure cut out. Commercial refrigeration install of a new high pressure cut out. Tested and confirmed operation.
Dan R.
Commercial refrigeration repair of a Delfield unit running warm. Discovered a failed temp control. Commercial refrigeration install of a new temp control. Tested and confirmed proper operation.
Nathan C.
Commercial refrigeration repair of a Traulsen 2 door reach in freezer running warm. Discovered a failed heating element used for the defrost. This cause the evaporator coil to ice up. Commercial refrigeration install of a new heating element. Tested and confirmed operation.
Karl P.
Commercial refrigeration repair of a Federal deli style reach in cooler with ice build up inside the unit. Found the evaporator coil was covered in ice. Discovered that the return air sensor was operating out of range. Commercial refrigeration install of a new return air sensor. Tested and confirmed operation.
Bob S.
Commercial refrigeration repair of a Manitowoc ice machine not producing ice. Discovered a failed water inlet valve, Commercial refrigeration install of a new water inlet valve. Tested and confirmed operation.
Dan R.
Commercial refrigeration repair of a Kolpak walk in cooler running too cold. Discovered that the liquid line solenoid was stuck open. Commercial refrigeration install of a new liquid line solenoid. Tested ans confirmed operation.
Nathan C.
Commercial refrigeration repair of a Norlake walk in freezer with frost build up in the box. Discovered a failed door frame heater in combination with a torn door sweep. Commercial refrigeration install of a new door frame heater and new door sweep. tested and confirmed operation and followed up to ensure that frost was gone.
John H.
Commercial refrigeration repair of a Traulsen 2 door stand up reach in cooler running warm. Discovered a failed expansion valve reducing the flow of refrigerant. Commercial refrigeration install of anew expansion valve and filter drier. Tested and confirmed operation.
Jonathan P.
Commercial HVAC repair of a Lennox roof top unit that is not cooling the space. Discovered that the condenser fan motor failed and fried that molex connector. Commercial HVAC install of a new wiring harness, condenser fan motor, fan blade, relay and capacitor. Tested and confirmed operation.
Ryan W.
Commercial HVAC repair of a Carrier Split system AC not cooling. Discovered that the condenser fan motor had failed. Commercial HVAC install of a new condenser fan motor, blade and capacitor. Tested and confirmed operation.
Karl P.
Commercial refrigeration repair of a Kolpak walk in cooler with a door that wont fully close. Discovered that the door threshold was the cause due to being bend out of shape. Commercial refrigeration install of a new door threshold. Tested and confirmed that the door closes properly.