Burlington MA
Medford Wellington Services Co., Inc. provides complete air conditioning, heating and refrigeration services to the residents and businesses of Burlington, MA. we are available 24/7 to meet your services needs.
If your commercial refrigerator is not cooling, the most likely reason is that the compressor is not running. Check to see if the compressor is running by opening up the cabinet and looking at the compressor. If it's not running, then you will need to call a refrigeration technician to come and fix it.
A commercial refrigeration system should be serviced every six months. This is because a commercial refrigeration system is under a lot more stress than a residential refrigerator. Commercial refrigerators are constantly running, which means that the compressor is always on. This also means that there is a greater chance of something going wrong with the system. Semiannual commercial refrigerator maintenance will ensure that it is running smoothly and that there are no problems with the compressor or any of the other components of the system.
There are a few things you can try to reset your compressor. One is to turn off the breaker to the refrigerator and wait about 5 minutes. Then turn it back on and see if that helps. Another thing you can try is to unplug the refrigerator for about 15 minutes and then plug it back in. If neither of those things work, then you may need to call a refrigeration technician.
Read reviews from our commercial and residential clients in Burlington, MA to see why they consider us to be their trusted local HVAC and refrigeration contractor.
Local Reviews
for Burlington, MA

Mark S.
Commercial refrigeration repair for a Continental Reach In Cooler that will not hold cool enough temps. Found the unit to have a fault tstat. Commercial refrigeration repair for a new internal thermostat.
Shawn H.
Commercial refrigeration repair for a Manitowoc Ice Machine that is not producing no ice. Found the unit has no water being fed. Commercial ice machine install for a new water pump, unit is good to go.
Tom K.
Commercial HVAC repair for a Trane RTU that is not responding to any calls for air conditioning. Found the tstat calling for AC and the unit not responding. Control board has died. Commercial HVAC install for a new control board, unit is fully operational.
Yanni F.
Commercial HVAC repair for a York RTU that is providing little air to the space. Went up to the unit and found that belt has come free and caused a mass amount of damage to the fan blades. Commercial HVAC install for a new fan and motor assembly.
Bill K.
Commercial refrigeration repair for a Hoshizaki ice machine that is no longer producing ice. Unit found and completely shut down. Power unit has failed. Commercial refrigeration install for a new power unit. Unit now operating normally.
Bill K.
Commercial refrigeration repair for a two-door True reach-in cooler that is leaking water. Found the unit to be iced over and dripping water. New fan needed. Commercial refrigeration install for a new condenser coil fan.
Anthony D.
Commercial HVAC repair for a Carrier air handler that is down. Found the units control board to have developed an issue. Commercial HVAC install for a new unit control module.
Adam F.
Commercial HVAC repair for a Lennox RTU that isn't providing enough cool air. Found the unit have a fan motor that is past its useful life. Commercial HVAC install for a new blower fan motor. Call is complete.
Nathan C.
Commercial refrigeration repair of a Norlake walk in cooler with the door not closing all the way. Found that the hydraulic door closer was no longer effective in closing the door. Commercial refrigeration install of a new hydraulic door closer. Tested and confirmed operation.
Scott F.
Commercial refrigeration repair of a Randell 3 door salad top reach in cooler leaking water inside the box. Discovered that the evaporator drain pan had a hole in the corner. Commercial refrigeration install a new evaporator drain pan.
Anthony D.
Commercial HVAC repair of a Trane split system AC not cooling. Discovered a failed blower motor causing the system to lock out on a safety. Commercial HVAC install of a new blower motor, pulley and contactor. Tested and confirmed operation.
Joe H.
Commercial refrigeration repair of a True 3 door counter top reach in cooler tripping the GFCI. Discovered that the starting components failed and were grounding out to the compressor. Commercial refrigeration install of a new set of starting components. Tested to ensure proper operation.
Jonathan P.
Commercial refrigeration repair of a Kolpak walk in freezer running warm. Discovered a refrigerant leak at the receiver. Commercial refrigeration install of a new receiver and filter drier. Tested and confirmed operation.
Shawn H.
Commercial refrigeration repair of a True 2 door stand up reach in cooler with a broken door hinge. Picked up new hinge kit and returned to site. Commercial refrigeration install of a new hinge kit. Confirmed proper operation.
Dan R.
Commercial refrigeration repair of a Heatcraft walk in cooler running warm. Discovered a failed duel pressure control. Commercial refrigeration install of a new duel pressure control. Tested and confirmed operation.
Bob S.
Commercial refrigeration repair of a Manitowoc flaker ice machine not producing ice. Discovered a failed auger motor. Commercial refrigeration install of a new auger motor. Tested and confirmed operation.
James A.
Commercial HVAC repair of a Carrier roof top unit running warm. Discovered a failed enthalpy sensor. Commercial HVAC install of a new enthalpy sensor. Tested and confirmed operation.
Daniel D.
Commercial HVAC repair of a Captive Air exhaust not pulling air from the space, Discovered that the motor failed. Commercial HVAC install of a new fan motor, pulley and belt, Tested and confirmed operation.
Shawn H.
Commercial refrigeration repair of a True 2 door counter top reach in cooler with water leaking out of the bottom. Found that the drain pan underneath the unit had a hole in the corner causing the condensate to leak out. Commercial refrigeration install of a new condensate drain pan with wicking kit.
Gregory S.
Commercial refrigeration repair of a Manitowoc ice machine not producing ice. Discovered a failed ice thickness probe. Commercial refrigeration install of a new ice thickness probe. Tested and confirmed operation.
Adam F.
Commercial refrigeration repair of a Randell 3 door reach in cooler leaking water from inside the unit. Discovered that the plastic evaporator drain pan had a small hole on one of the corners. Commercial refrigeration install of a new evaporator drain pan.
Adam F.
Commercial HVAC repair of a Carrier Make up air with chilled water coil not cooling. Discovered a failed water actuator valve. Commercial refrigeration install of a new water actuator valve. Tested and confirmed operation.
Daniel D.
Commercial refrigeration repair of a Hoshizaki ice machine not producing ice. Upon arrival the unit was locked out on an extended freeze. Discovered that the float switch failed. Commercial refrigeration install of a new float switch. Tested and confirmed operation.
James A.
Commercial refrigeration repair of a Heatcraft walk in freezer running warm. Discovered a failed defrost time clock. Commercial refrigeration install of a new defrost time clock. Tested and confirmed proper operation.

Mark S.
Commercial HVAC repair of a Lennox roof top unit not cooling. Discovered a failed stage 1 Compressor. Commercial HVAC install of a new stage 1 compressor and filter drier. Tested and confirmed proper operation.